Static and dynamic tests on the I’D L - Petzl United Kingdom
Search

Static and dynamic tests on the I’D L

The following tests were carried out in laboratories, with new devices and new ropes certified to current standards. Test results are given for information purposes only: they may be different with devices and/or ropes that are worn from use, or with other rope types or models.

Warnings

  • Carefully read the Instructions for Use used in this technical advice before consulting the advice itself. You must have already read and understood the information in the Instructions for Use to be able to understand this supplementary information.
  • Mastering these techniques requires specific training. Work with a professional to confirm your ability to perform these techniques safely and independently before attempting them unsupervised.
  • We provide examples of techniques related to your activity. There may be others that we do not describe here.

A. Tests on the 2019 I’D L

A. Tests on the 2019 I’D L

Slow-pull test carried out on different ropes; the measured value is the load at which the rope begins to slip in the device.

Tests on the 2019 I’D L.

A2: Dynamic tests on the 2019 I’D L

Fall arrest tests carried out during EN 12841, EN 341, EN 15151 and NFPA certifications, and during additional Petzl tests designed to cover exceptional situations.

Note: not all of the tests carried out are cited here, only those yielding relevant information on I’D use.

EN 12841 certification test - Device on 1 m of rope, 1 m fall on a 1 m x 11 mm dynamic rope lanyard.

Dynamic tests on the 2019 I’D L.
Dynamic tests on the 2019 I’D L, table.

NFPA certification test with rigid mass.

Additional Petzl tests with dummy and harness - 60 cm fall on 3 m of rope.

Dynamic tests on the 2019 I’D L.
Dynamic tests on the 2019 I’D L, table.

B. Archive: tests on the pre-2019 I’D L

B1: dynamic tests on the pre-2019 I’D L

Test conditions:

- Rope length: 2 m

- Mass: 100 kg

The values given are averages; they vary depending on the rope models used.

Dynamic tests on the pre-2019 I’D L.
Dynamic tests on the pre-2019 I’D L, table.

B2: static tests on the pre-2019 I’D L

These tests were carried out using a slow pull.

Static tests on the pre-2019 I’D L.