The ATEX marking

The ATEX marking is found on the product and on its Instructions for Use.

Warnings

  • Carefully read the Instructions for Use used in this technical advice before consulting the advice itself. You must have already read and understood the information in the Instructions for Use to be able to understand this supplementary information.
  • Mastering these techniques requires specific training. Work with a professional to confirm your ability to perform these techniques safely and independently before attempting them unsupervised.
  • We provide examples of techniques related to your activity. There may be others that we do not describe here.

Meaning of the ATEX marking:

Example of ATEX marking
Example of ATEX marking
Example of ATEX marking

This product is thus designed to be used in an above-ground industrial environment, in zone 1 with group IIB gas (e.g. ethylene) present. The product's surface temperature will not exceed 85° C: thus care must be taken to not use this product in the presence of gas having an ignition temperature of less than 85° C

ATEX marking detail for PIXA 1, 2 and 3 headlamps:

These 3 lamps have the same ATEX marking:

Ex II 3 GD

Ex nA ic IIB T4 Gc

Ex tc IIIC T135° C Dc

  • General marking Ex II 3 GD

    II: above-ground industry.

    3 GD: category of 3GD lamps that determines the zone of use, in this case zone 2/22 (gas/dust)
  • ATEX zone 2 protection: gas-specific marking: Ex nA ic IIB T4 Gc

    nA: protection mode against risk of sparking

    ic: intrinsically safe protection mode

    IIB : lamp designed for an environment presenting a type of gas belonging to the IIB gas group

    T4: maximum surface temperature of the lamp: 135° C

    Gc: normal protection level
  • ATEX zone 22 protection: dust-specific marking: Ex tc IIIC T135° C Dc

    tc: enclosure protection mode

    IIIC: lamp designed for an environment presenting a dust type belonging to dust group IIIC

    T135°C: maximum lamp temperature: 135° C

    Dc: normal protection level

(1) Examples of protection modes:

tD: protection by enclosure for electrical equipment for dust hazard

mD: encapsulation for electrical equipment for dust hazard

iD: intrinsic safety for electrical equipment for dust hazard

n: non-incendive for electrical equipment for gas hazard

nA: non-sparking (zone 2 or Gc)

nR: restricted breathing (zone 2 or Gc)

nL: energy limitation (zone 2 or Gc)

nC: sealed device (zone 2 or Gc)

ma/mb: encapsulation for electrical equipment for gas hazard

c: protection by construction for non-electric equipment, e.g. mechanical

ic: intrinsic safety for electrical equipment for gas hazard (zone 2 or Gc)